Mar 19 14:32:16 syslog: Linesync lost
Mar 19 14:32:29 DHCP client: Broadcast a release
Mar 19 14:32:29 DHCP client: Sending release...
Mar 19 14:32:30 DHCP client: Entering released state
Mar 19 14:32:38 syslog: Linesync achieved
Mar 19 14:32:38 syslog: near-end interleaved channel bit rate: 8064 kbps
Mar 19 14:32:38 syslog: near-end fast channel bit rate: 0 kbps
Mar 19 14:32:38 syslog: far-end interleaved channel bit rate: 832 kbps
Mar 19 14:32:38 syslog: far-end fast channel bit rate: 0 kbps
Mar 19 14:32:44 DHCP client: Performing a DHCP renew
Mar 19 14:32:44 DHCP client: Sending discover...
Mar 19 14:32:44 syslog: vc=0: change the peak rate
Soneran myöntämä viiden megan kuristin siis otettiin pois tuolla yllä näkyvällä kellonlyömällä. Toivottavasti linjalla on tapahtunut jotain oikeita korjaustoimenpiteitäkin. No, seurataan syslogia...ja ilmankosteutta...vesisateella se sitten taas nitkahtaa jos ei ole korjattu.
Telewellin linjatesti kertoo seuraavaa:
Mar 19 18:55:24 syslog: ADSL link status: up
Mar 19 18:55:24 syslog:
Mar 19 18:55:24 syslog: Opmode: ITU G.992.1(G.DMT)
Mar 19 18:55:24 syslog:
Mar 19 18:55:24 syslog: near-end interleaved channel bit rate: 8064 kbps
Mar 19 18:55:24 syslog: near-end fast channel bit rate: 0 kbps
Mar 19 18:55:24 syslog: far-end interleaved channel bit rate: 832 kbps
Mar 19 18:55:24 syslog: far-end fast channel bit rate: 0 kbps
Mar 19 18:55:24 syslog:
Mar 19 18:55:24 syslog: near-end FEC correctable error fast: 0
Mar 19 18:55:24 syslog: near-end FEC correctable error interleaved: 32096
Mar 19 18:55:24 syslog: near-end CRC error fast: 0
Mar 19 18:55:24 syslog: near-end CRC error interleaved: 1401
Mar 19 18:55:24 syslog: near-end HEC error fast: 0
Mar 19 18:55:24 syslog: near-end HEC error interleaved: 1363
Mar 19 18:55:24 syslog: far-end FEC correctable error fast: 0
Mar 19 18:55:24 Mar
Mar 19 18:55:24 9 18:55:24 syslog: far-end FEC correctable error interleaved: 776
Mar 19 18:55:24 syslog: far-end CRC error fast: 0
Mar 19 18:55:24 syslog: far-end CRC error interleaved: 787
Mar 19 18:55:24 syslog: far-end HEC error fast: 0
Mar 19 18:55:24 syslog: far-end HEC error interleaved: 616
Mar 19 18:55:24 syslog:
Mar 19 18:55:24 syslog: Downstream:
Mar 19 18:55:24 syslog: relative capacity occupation: 78%
Mar 19 18:55:24 syslog: noise margin downstream: 13.5 db
Mar 19 18:55:24 syslog: output power upstream: 12.5 dbm
Mar 19 18:55:24 syslog: attenuation downstream: 23.0 db
Mar 19 18:55:24 syslog:
Mar 19 18:55:24 syslog: Upstream:
Mar 19 18:55:24 syslog: relative capacity occupation: 79%
Mar 19 18:55:24 syslog: noise margin upstream: 9.0 db
Mar 19 18:55:24 syslog: output power downstream: 19.5 dbm
Mar 19 18:55:24 syslog: attenuation upstream: 11.0 db
Near-end CRC erroreitahan tuolla kyllä näkyy reilusti olevan, hmmmm.....
Hämmästyttää kummastuttaa.....nopeus nousi takaisin 8 Mbps
Enter your E-mail address. We'll send you an e-mail with instructions to reset your password.